Hydroxy Generator

The high-efficiency Hydroxy Generator is compact and easy to operate, and specifically safe because there is not an explosive hazard like LPG gas containers. Therefore, the Hydroxy gas is used as a necessary and useful flame for every thermal process.

Share product


Gas Mixed Combustion System

Hydroxy mixed combustion system is a new combustion technology. If HHO plants are installed with existing equipment (Industrial large-scale boilers, heating furnaces, melting furnaces etc.) that use fossil fuels (diesel, LNG, LPG etc). The hydroxy gas from EnerTek HHO generator is mixed and burned with fossil fuels. It makes the combustion acceleration to save the fuel.

Hydroxy mixed combustion system has an advantage that it can use the existing equipment as it is without modifying too much or making newly. The fuel savings rates are from 10% to 30% according to the quantity of hydroxy gas and CO2 is reduced as much as the saved fuel. Therefore, we can say it is a green revolution of low carbon.

Water Energy incinerator

Hydroxy Water Energy Incinerator system is working in high-temperature pyrolysis melting incinerator by water energy system. It is composed and linked of Hydroxy Plant and Hydroxy Gas melting incinerator by the unique heat generation technology of Hydroxy gas.

This melting incineration technology is a new technology. A combustion chamber is prepared in the incinerator and it has the complete combustion condition of Hydroxy gas. Combustion heat of syngas and combustion heat of Hydroxy gas make synergy each other to create high temperature of 1400-1800˚C. It can melt everything and it doesn’t produce any ash, the problem of existing incinerators.

Application

  1. Jewelry working
  2. Soldering
  3. Glass working
  4. School, Laboratory
  5. Brazing
  6. Gas welding
  7. Gas cutting
  8. Heat treatment
  9. Slab cutting for steel mill
  10. Heavy Industry Process
  11. Industrial Boiler
  12. Industrial Heating furnace
  13. Industrial Melting furnace
  14. Waste melting incinerator
  15. Mixed Combustion System

HHO Sizes & Technical Specifications

HHO-500 LPHHHO-300 LPHHHO-1000 LPHHHO-5000 LPHHHO-10000 LPHHHO-50000 LPH
Gas Production (l/h)6003001000200020002000
Voltage (Volt)415415415415415415
Phase (ø)333
3
33
Water Consumption (l/h)0.32
0.16
0.63.03.03.0
Power Consumption (kWh)2.21.13.015.0
15.0

15.0
Max. Operation pressure (kg/cm2)1.0
1.0
1.01.01.01.0
Weight (kg)12080
200
350350350
Size (WxHxL) (mm)770 x 1300 x 770700 x 1300 x 7001200 x 1550 x 8002500 x 1550 x 10002500 x 1550 x 1000
2500 x 1550 x 1000
HHO Sizes & Technical Specifications
Share product